Description
Technical Specifications
| Specification | Value |
|---|---|
| Product Code | HV-FR-300 |
| Composition | 99% Cotton / 1% Conductive Fiber (Inherent IFR variant: 60% Modacrylic / 38% Cotton / 2% Conductive Fiber) |
| Weight | 300 GSM (±5%) |
| Width | 150 cm / 59″ (usable) |
| Weave | Twill 3/1 |
| FR Technology | THPC (Proban) — ammonia cure, durable finish (IFR variant available) |
| Wash Durability | FR efficacy retained after 50+ industrial washes (ISO 15797) |
| Afterflame Time | ≤2 seconds (EN ISO 15025 / GB/T 14644) |
| Afterglow Time | ≤2 seconds |
| Char Length | ≤100 mm |
| Hi-Vis Standard | EN ISO 20471 — Class 2 (fluorescent background) |
| Retroreflective Compatibility | Compatible with EN ISO 20471 compliant reflective tape |
| Fluorescent Colors | Fluorescent Orange, Fluorescent Yellow |
| Fluorescent Durability | ≥20 washes to maintain minimum chromaticity (ISO 20471) |
| Anti-Static | Standard — 1% conductive carbon fiber (EN 1149) |
| Shrinkage | ≤3% after 50 washes (ISO 6330) |
| Colorfastness to Washing | Grade 4 (ISO 105-C06) |
| Colorfastness to Light | Grade 4 (ISO 105-B02) |
| Tensile Strength (Warp) | ≥1000 N (ISO 13934-1) |
| Tear Strength (Weft) | ≥25 N (ISO 13937-2) |
| Abrasion Resistance | ≥25,000 Martindale cycles |
| Finishing | FR treated + fluorescent dye + anti-static |
Standards & Certifications
| Standard | Status |
|---|---|
| EN ISO 20471 Class 2 | ✅ Hi-Vis — high-visibility clothing for professional use |
| GB 8965.1-2020 | ✅ FR — Class B |
| EN ISO 11612 (A1, B1) | ✅ Heat & flame |
| EN ISO 11611 (Class 1) | ✅ Welding |
| NFPA 2112 | ✅ Flash fire (cotton variant) |
| EN 1149 | ✅ Anti-static — standard, not optional |
| OEKO-TEX Standard 100 | ✅ Available upon request |
| ISO 15797 | ✅ Industrial wash — 50-cycle certified |
Why Three Functions in One Fabric?
Workers in road maintenance, emergency rescue, gas utility, and railway environments face multiple hazards simultaneously:
| Hazard | Protection Required | HV-FR-300 Solution |
|---|---|---|
| Moving vehicles / traffic | High visibility — fluorescent color + reflective tape | EN ISO 20471 Class 2 certified fluorescence |
| Flame / flash fire | Flame retardant clothing | EN ISO 11612 certified FR treatment |
| Explosive atmosphere (gas leak) | Anti-static — no spark generation | EN 1149 certified — 1% conductive fiber standard |
| Molten metal (cutting/grinding) | Welding protection | EN ISO 11611 Class 1 certified |
A worker responding to a gas leak on a roadside needs all three protections simultaneously. HV-FR-300 delivers them in a single fabric specification.
Fluorescent vs. Standard Colors — The Difference
Standard FR fabrics in Orange or Yellow are safety-colored but not fluorescent. Under low-light conditions (dusk, dawn, overcast, tunnel), they blend into the background. Fluorescent fabrics convert invisible UV light into visible light — appearing to “glow” in conditions where standard colors disappear.
| Condition | Standard Orange FR | Fluorescent Orange FR (HV-FR-300) |
|---|---|---|
| Daylight | Visible | Visible — similar |
| Dusk/dawn | Poor — blends | Highly visible — fluoresces |
| Overcast/rain | Poor | Good — UV penetrates clouds |
| Tunnel/shade | Poor | Moderate improvement |
| Night (with reflective tape) | Tape only visible | Tape + fluorescent background visible in headlights |
Anti-Static — Why It Is Standard (Not Optional)
HV-FR-300 includes 1% conductive carbon fiber as standard equipment, not an optional add-on. The reasoning:
- The most common applications for hi-vis FR (gas utility, emergency rescue, fuel tanker loading) involve explosive atmospheres
- A static discharge from non-anti-static clothing in a gas-leak environment can be fatal
- Adding conductive fiber at the spinning stage costs approximately 3–5% more and adds zero maintenance burden
- There is no reason to offer hi-vis FR without anti-static
If EN 1149 certification is not required (e.g., roadside construction without explosion risk), contact us for a non-AS variant. We do not stock it by default.
Inherent FR (IFR) Variant
For programs requiring unlimited wash durability, zero formaldehyde, or chemical splash resistance, HV-FR-300 is also available in an inherent modacrylic/cotton blend:
- HV-IFR-300: 60% Modacrylic / 38% Cotton / 2% Conductive Fiber
- Same weight (300gsm), same Hi-Vis Class 2 certification
- Permanent FR — unlimited washes
- Zero formaldehyde
- EN 13034 limited chemical splash
- Higher cost (+40–50%) — use for chemical, pharmaceutical, long-life programs
Applications
| Application | Why HV-FR-300 |
|---|---|
| Road maintenance & construction crews | EN ISO 20471 Class 2 hi-vis + FR for asphalt work near traffic |
| Gas utility emergency response | Gas leaks create explosion risk — FR + anti-static + hi-vis required simultaneously |
| Emergency rescue services (fire, ambulance) | FR for fire scenes + hi-vis for roadside incident management |
| Railway maintenance & track work | Hi-vis for rail corridor + FR for welding/cutting near tracks |
| Oil & gas pipeline emergency crews | Explosive atmosphere + traffic zone — all three protections needed |
| Airport ground crew (fuel handling) | Hi-vis for apron operations + FR + anti-static for fuel areas |
| Electrical utility — roadside repair | Substation and pole work near traffic — arc flash + hi-vis |
| Towing and roadside assistance | Hi-vis for traffic + FR for cutting/grinding during vehicle extrication |
Available Variants
| Variant | Product Code | Description |
|---|---|---|
| Cotton FR — Standard | HV-FR-300 | 99% Cotton / 1% AS — THPC treated — 50-cycle FR |
| Cotton + Water-Repellent | HV-FR-300-WR | + DWR finish for wet weather |
| Inherent FR (IFR) | HV-IFR-300 | 60/38/2 Modacrylic — permanent FR — unlimited washes |
| Inherent + DWR | HV-IFR-300-WR | Permanent FR + water-repellent |
Color Options
Stock Colors (2 — held in continuous inventory):
| Color | Standard | Application |
|---|---|---|
| Fluorescent Orange | ✅ Stock | Road construction, utility, rescue — most specified globally |
| Fluorescent Yellow | ✅ Stock | Railway, airport, some EU markets |
Custom Color: Not applicable — fluorescent colors are limited to Orange and Yellow by EN ISO 20471 standard.
Reflective Tape Integration
HV-FR-300 is designed for assembly with EN ISO 20471 compliant retroreflective tape. We supply the fabric only — tape application is performed by the garment manufacturer.
Minimum tape requirement for EN ISO 20471 Class 2:
- ≥0.10 m² fluorescent background material
- ≥0.13 m² retroreflective material (tape)
- Tape width: ≥50mm
Typical configuration: 2 horizontal bands around torso + 2 bands around each sleeve.
Ordering Information
| Parameter | Details |
|---|---|
| Stock color MOQ | 200 meters per color |
| Custom weave / IFR variant MOQ | 500 meters per variant |
| A4 sample swatch | Free, 3 working days |
| Bulk lead time (stock) | 15–20 days |
| Bulk lead time (IFR variant) | 25–30 days |
| Packing | Roll on tube, polybag, export carton |
| Shipping | FOB Shanghai / CIF / DDP — air, sea, express (DHL, FedEx) |
Care Instructions
| Step | Instruction |
|---|---|
| Washing | Machine wash 60°C, normal cycle |
| Bleaching | Do not bleach — chlorine degrades both FR treatment and fluorescent dye |
| Drying | Tumble dry medium — avoid prolonged high heat (fluorescent dye sensitive) |
| Ironing | Medium iron (150°C) — do not iron directly over reflective tape |
| Reflective tape | Wash with tape attached — avoid fabric softener (reduces tape reflectivity) |
⚠️ Fluorescent-specific care: Fluorescent dyes are inherently less wash-fast than standard dyes. EN ISO 20471 requires the fabric to maintain minimum chromaticity and luminance for 20 washes. After 20 washes, the fluorescent effect gradually fades but the FR and anti-static protections remain fully functional. For extended fluorescent life, wash at 40°C (not 60°C) and hang dry in shade. The FR treatment is not affected by lower wash temperature.
FAQ
Q: What is the difference between EN ISO 20471 Class 2 and Class 3? A: Class 3 requires more fluorescent and reflective material than Class 2 — typically a full-sleeve garment (coverall or jacket with full-length sleeves). HV-FR-300 fabric meets Class 2 background material requirements at 300gsm. Class 3 can be achieved by using this fabric in a full-coverage garment design with additional reflective tape area. The fabric itself is the same.
Q: How long does the fluorescent color last? A: EN ISO 20471 certifies the fabric to maintain minimum chromaticity for 20 industrial washes. In practice, the fluorescent effect is visually acceptable for 30–40 washes before noticeable fading occurs. The FR and anti-static properties are unaffected by dye fading. The garment remains fully protective — it just becomes less bright.
Q: Can I wash this fabric with reflective tape already attached? A: Yes. The tape should be applied by the garment manufacturer before delivery. Wash with tape attached. Do not use fabric softener — it coats the reflective beads and reduces reflectivity. Do not iron directly over the tape.
Q: Which color is more visible — Orange or Yellow? A: Orange is more visible in natural environments (greens, browns, greys) — it offers higher contrast. Yellow is more visible in urban environments (concrete, asphalt). Orange accounts for approximately 70% of global hi-vis FR fabric orders. Yellow is standard for railway and some European markets.
Q: Is anti-static really necessary for roadside construction? A: For general roadside construction without explosion risk, anti-static is not strictly required. However, since the same crew may respond to gas leaks or work near fuel storage, many safety programs specify FR + anti-static + hi-vis as a single standard for all field workers. HV-FR-300 has anti-static built in as standard — it cannot be ordered without it.
Q: Do you supply reflective tape as well? A: No — we supply the fluorescent FR fabric only. Reflective tape is applied by the garment manufacturer. We can recommend compatible tape specifications and suppliers upon request.
















Reviews